Finding the best rapid start ballast 1 lamp suitable for your needs isnt easy. With hundreds of choices can distract you. Knowing whats bad and whats good can be something of a minefield. In this article, weve done the hard work for you.
Best rapid start ballast 1 lamp
1. ROBERTSON 3P20116 eBallast, Instant Start, NPF, 1 or 2 Lamp F32T8, 120Vac, 60 Hz, Model ISU232T8120 BA (Replaces Robertson 3P20003, Model ISU232T8120 /B)
Feature
Equivalent to: Philips-Advance REL-2P32SC, REB2P32SC; General Electric GE-232-120-N; Universal B232I120RH-A, B232I120RESA; Osram QT2X32T8120ISNSCEquivalent to: Keystone KTEB-232LBF-1-TP-PIC-EV; Aspen VE232120HIP, VE232120MIP; Howard E2/32IS/120SC; Sola E-758-F-232-SC
Parallel lamp connection, Encased and potted, Sound Rated A, Internal surge protection
Meets FCC Part 18 (Class B) consumer limits, Meets ANSI standard C82.11 for ballast requirements, Meets ANSI C62.41 for transient protection
Max case temp: 167F/75C, Max ambient temp: 104F/40C, Min starting temp: 0F/-18C, Lamp starts: >15,000. Remote Mounting: 18 ft., Rugged steel case
Description
Robertson 3P20116, Model ISU232T8120 Fluorescent Electronic Linear T8 Instant Start Ballast for 2 or 1 F32T8 lamps operation. Ballast also accepts 2/1 F32T8U, F28T8U, F25T8, F25T8U, F17T8 and F17T8U or 1 F40T8 lamps. Low profile housing and lightweight. High performance ballast for all general fluorescent applications. Dimensions 9.50 L x 1.16 W x 0.91 H and 8.94 M. Parallel lamp operation keeps the unit maintenance easier to manage, if one lamp fails others will stay on. Unit is thermally protected and features an internal surge protection. Sound rating of Class A. Normal ballast factor. Normal power factor. Meets FCC Part 18 (Class B) EMI and RFI consumer limits. Meets ANSI standard C82.11 for ballast requirements. Meets ANSI standard C62.41 for transient protection. UL/935 (Class P, Typ3 HL, Type 1 Outdoor) listed. cull (CSA C22.2) listed. ROHS Compliant. Maximum case temperature 167F/75C, Maximum ambient temperature 104F/40C. Minimum starting temperature 0F/-18C. Industry standards for safety and performance.2. ROBERTSON 3P20132 Fluorescent eBallast for 2 F40T12 Linear Lamps, Preheat- Rapid Start, 120Vac, 50-60Hz, Normal Ballast Factor, NPF, Model RSW234T12120/A (Crosses to 3P20010 Model RSW240T12120/B)
Feature
Please make certain to review spec sheet for lamp compatibility, product dimensions and wiring diagram.Please note that form, fit and electrical specifications may not be a direct replacement to all recommended crosses.
Crosses to Philips-Advance REL2S40SC, Osram QTP2X40T12120RSNSC, Universal B240R120HP
Crosses to Keystone KTEB-240-1-TP, General Electric GE 97499, GE240RS120-DIY,Fulham WHCG9127T12RS
Save and order the 2P20132 Quik-Pak of 10 units individually packaged
Description
ROBERTSON 3P20132 Fluorescent eBallast for 2 F40T12 Linear Lamps, Preheat- Rapid Start, 120Vac, 50-60Hz, Normal Ballast Factor, NPF, Model RSW234T12120 /A (Crosses to 3P20010 Model RSW240T12120 /B)3. GE Lighting 74472 GE240RS-MV-N 120/277-Volt Multi-Volt ProLine Electronic Fluorescent T12 Programmed Rapid Start Ballast 2 or 1 F40 or F34T12 Lamps
Feature
Programmed Rapid Start T12 Ballast will accept up to 2 or 1 F40 or F34T12 lampsAccommodates multi-voltages from 120 to 277-volts, extra versatile for your unique projects
High performance rapid start electronic ballast is for all general fluorescent applications
Low profile housing and lightweight for portability
Mounting dimensions: 8.9-Inch L x 1.1-Inch W, Mounting slot set 1.06-Inch apart
Description
GE 74472 GE240RS-MV-N 120/277-volt Multi-Volt ProLine Electronic Fluorescent T12 Programmed Rapid Start Ballast, 2 or 1 F40 or F34T12 lamps. Programmed Rapid Start T12 Ballast will accept up to 2 or 1 F40 or F34T12 lamps. Accommodates multi-voltages from 120 to 277-volts, extra versatile for your unique projects. High performance rapid start electronic ballast is for all general fluorescent applications. Low profile housing and lightweight for portability. Mounting dimensions: 8.9-Inch L x 1.1-Inch W, Mounting slot set 1.06-Inch apart. Multi-Volt ProLine T12 Electronic Fluorescent ballasts meet the Dept. of Energy minimum ballast efficiency requirements. Multi-volt and dedicated voltage ProLine T12 ballasts may be used to replace existing magnetic T12 electronic ballasts during maintenance or retrofits. Parallel lamp operation keeps the unit maintenance easier to manage, if one lamp fails others will stay on. Unit provides auto-restart functions and thermal protection. T12 ballast sound rating: Class A (20-24 decibels). Ballast factor rating of Normal .87 for full light output, ballast factor rating controls light output and wattages of each lamp, a lower BF will reduce light output and wattage of each lamp, meaning more lamps would be needed to achieve a certain foot-candle level in the same area. UL Type 1 Outdoor, UL Type HL, UL Class P, ETL NRCan, CUL Listed, and ROHS Compliant - Industry standards for safety and performance.4. Advance ICN-2S40-N Centium Fluorescent Ballast - for 2x40W T12
Feature
Electronic Fluorescent120/277 V
Ballast Factor: 0.85
(2) Lamps
Rapid Start
Description
The Advance ICN-2S40-N-35I electronic fluorescent ballast operates (2) F40T12 or F34T12 lamps at 120/277 input volts and has a maximum input power of 72 watts. Ideal for use in normal light areas, this rapid start ballast is typically used in offices, board rooms, and retail.5. ROBERTSON 3P20128 Fluorescent eBallast for 1 CFQ26W/G24q CFL Lamp, Preheat Rapid Start, 120Vac, 50-60Hz, Normal Ballast Factor, NPF, Model RSO126CQ120 AA (Replaces Model RSO126CQ120 /A)
Feature
Equivalent to Philips-Advance REB-126-M6, Osram QTR1X26CF 120V, Universal CBT126L-120SEquivalent to Keystone KTEB-126-1-TP-SC /H, Hatch FR2600LH, Fulham NPY120126CFL
Save by ordering the Quik-Pak of 10 individually packaged ROBERTSON units 2P20128
Save the most with the 1P20128 carton of 20 units, not individually packaged
Go to RobertsonDirect.com for complete technical data.
Description
Fluorescent eBallast, 1 CFQ26W/G24q CFL Lamp, Preheat-Rapid Start, 120Vac, 50-60Hz, Normal Ballast Factor, NPF, Model RSO126CQ120 AA (Replaces Model RSO126CQ120 /A)6. (10 Pack) GE Lighting 72275 GE232-MV-N 120/277-Volt Multi-Volt ProLine Electronic Fluorescent T8 Instant Start Ballast 2 or 1 F32T8 Lamps
Feature
Instant Start T8 Ballast will accept up to 2 or 1 F32T8 lampsAccommodates multi-voltages from 120 to 277-volts, extra versatile for your unique projects
Instant start electronic ballast for long lamp starting cycles and low initial cost
High performance instant start electronic ballast is for all general fluorescent applications
Description
(10 Pack) GE Lighting 72275 GE232-MV-N 120/277-Volt Multi-Volt ProLine Electr...7. Advance Transformer #ICN2P32SCI F17-32 Intel Ballast
Feature
Brand: Advance- Family: Centium
- Part No.: ICN-2P32-N
- UPC: 30781087069128
- Voltage: 120 / 277
Description
F32T8 - (1-2 Lamps) - 120-277 Volt - Normal Light Output - Low Profile Ballast - Advance Centium ICN-2P32-N8. GE Lighting 96720 GE232-MVPS-L 120/277-Volt UltraStart Electronic Fluorescent T8 Programmed Rapid Start Ballast 2 or 1 F32T8 Lamps
Feature
Programmed Rapid Start T8 Ballast will accept up to 2 or 1 F32T8 lampsAccommodates multi-voltages from 120 to 277-volts, extra versatile for your unique projects
Extends lamp life in frequently switched applications, more than 100,000 on/off cycles
Ultra-efficient programmed start ballasts with more than 90-Percent efficiency
Mounting dimensions: 8.9-Inch L x 1.1-Inch W, Mounting slot set 0.3-Inch apart
Description
GE 96720 GE232-MVPS-L 120/277-volt Ultra Start Electronic Fluorescent T8 Programmed Rapid Start Ballast, 2 or 1 F32T8 lamps. Programmed Rapid Start T8 Ballast will accept up to 2 or 1 F32T8 lamps. Accommodates multi-voltages from 120 to 277-volts, extra versatile for your unique projects. Extends lamp life in frequently switched applications, more than 100,000 on/off cycles. Ultra-efficient programmed start ballasts with more than 90-Percent efficiency. Mounting dimensions: 8.9-Inch L x 1.1-Inch W, Mounting slot set 0.3-Inch apart. Ultra Start ballasts provide greater than 100,000 starts and have the equivalent energy savings of instant start ballasts. additionally offering a long lamp life similar to a programmed start ballast. Runs quietly with most 120-volt applications, less than 10-Percent Total Harmonic Distortion (THD). Anti-striation circuitry helps to eliminate and prevent the spiraling effect from lights. T8 ballast sound rating: Class A (20-24 decibels). Ballast factor rating of Low .77 for low power maximum savings, ballast factor rating controls light output and wattages of each lamp, a lower BF will reduce light output and wattage of each lamp, meaning more lamps would be needed to achieve a certain foot-candle level in the same area. Parallel lamp operation keeps the unit maintenance easier to manage, if one lamp fails others will stay on. Unit features anti-striation control, thermal protection, and universal voltage. UL Type 1 Outdoor, UL Type HL, UL Class P, ANSI C62.41, NEMA Premium, ROHS Compliant - Industry standards for quality and safety.9. (10 Pack) Advance ICN2P32N F32T8 - 1-2 Lamps - 120-277 Volt - Normal Light Output - Low Profile Ballast
Feature
Centium ICN-2P32-N Instant Start Electronic Ballast1 Or 2 Lamp 32W T8 Electronic Fluorescent Ballast
120V To 277V 50/60hz
Also Starts 2 17W T8 2 Foot Ballasts
120-277V
Description
F32T8 - (1-2 Lamps) - 120-277 Volt - Normal Light Output - Low Profile Ballast - Advance Centium ICN-2P32-N10. Advance RCN-1S32-SC Electric Lamp Ballast 120V 60Hz
Feature
High Power FactorClass P, Type 1 Outdoor
Program Rapid-Start Electronic Ballast
120 Volts
0.29 Amps, 60 Hz